Installation; Configuration Switch Pre-Check; Mic Kill Dip Switch (Dip Switch 1); Dc Call Enable (Dip Switch 2) - Telex Audiocom WM1000 User Instructions

Audiocom wm1000/2000 wall mount intercom station
Hide thumbs Also See for Audiocom WM1000:
Table of Contents

Advertisement

Installation

Configuration Switch Pre-check

Before making connections, read the configuration switch notes that follow and make
sure all switches are properly set for your intended usage. Chapter 1, "Configuration
Switch Settings," on page 7 lists the switch descriptions and factory default settings.
The location of the DIP switches are shown in Figure 1 on page 2.

Mic Kill DIP Switch (DIP Switch 1)

Audiocom master stations can transmit an inaudible signal to turn off the microphones
in all remote intercom stations (including WM1000/2000) on an intercom channel.
This is useful when a remote intercom station has been left unattended with the
microphone on. However, you may wish to disable the mic kill feature at the
WM1000/2000, if communications are critical in nature where it is absolutely
essential the microphone never be remotely disabled.

DC Call Enable (DIP Switch 2)

Leave this switch in the open position for Audiocom applications. Set it to the closed
position if the WM1000/2000 will be used in a Clear-Com intercom system.

Incoming Call Beep (DIP Switch 3)

By default, incoming calls are indicated by a red-flashing Call key and a beep tone in
the headphones. If you do not want the beep tone, set DIP switch 3 to the closed
position.
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Audiocom wm2000

Table of Contents