Note For Multi System - Daikin G-Series Service Manual

Inverter multi for 2 rooms
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

Instruction

2.1.12 Note for Multi System

Note for Multi System
〈〈
What is a "Multi System"?
This system has one outdoor unit connected to multiple indoor units.
Selecting the Operation Mode
1. With the Priority Room Setting
present but inactive or not present.
When more than one indoor unit is operating, priority
is given to the first unit that was turned on.
In this case, set the units that are turned on later to
the same operation mode (*1) as the first unit.
Otherwise, they will enter the Standby Mode, and the
operation lamp will flash; this does not indicate malfunction.
(*1)
• COOL, DRY and FAN mode may be used at the same time.
• AUTO mode automatically selects COOL mode or HEAT mode based on the room temperature.
Therefore, AUTO mode is available when selecting the same operation mode as that of
the room with the first unit to be turned on.
CAUTION
Normally, the operation mode in the room where the unit is first run is given priority, but the
following situations are exceptions, so please keep this in mind.
If the operation mode of the first room is FAN Mode, then using Heating Mode in any room
after this will give priority to heating. In this situation, the air conditioner running in FAN Mode
will go on standby, and the operation lamp will flash.
2. With the Priority Room Setting active.
See "Priority Room Setting" on the next page.
NIGHT QUIET Mode (Available only for cooling operation)
NIGHT QUIET Mode requires initial programming during installation. Please consult your retailer or
dealer for assistance.
NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to
prevent annoyance to neighbors.
• The NIGHT QUIET Mode is activated when the temperature drops 5°C or more below the highest temperature
recorded that day. Therefore, when the temperature difference is less than 5°C, this function will not be activated.
• NIGHT QUIET Mode reduces slightly the cooling efficiency of the unit.
OUTDOOR UNIT QUIET Operation
1. With the Priority Room Setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor
units to OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using
their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.
2. With the Priority Room Setting active.
See "Priority Room Setting" on the next page.
Cooling / Heating Mode Lock (Available only for heat pump models)
The Cooling / Heating Mode Lock requires initial programming during installation.Please consult
your retailer or dealer for assistance. The Cooling / Heating Mode Lock sets the unit forcibly to
either Cooling or Heating Mode. This function is convenient when you wish to set all indoor units
connected to the Multi system to the same operation mode.
126
〉〉
A
room
Outdoor
unit
room
Living
room
C
room
SiBE12-933_A
B
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents