SiBE12-933_A
Caution:
Operation stops suddenly. (Operation lamp blinks.)
Cause of above trouble could be "Operation mode butting".
Check followings;
Are the operation modes all the same for indoor units connected to Multi system outdoor unit?
If not set all indoor units to the same operation mode and confirm that the operation lamp is not
blinking.
Moreover, when the operation mode is in "Auto", set all indoor unit operation mode to "Cool" or
"Heat" and check again if the operation lamp is normal.
If the lamp stops blinking after the above steps, there is no malfunction.
mode is set later. (The first set operation mode has priority.)
Troubleshooting
Outdoor Unit
with the LED
There is a green LED on the PCB. The flashing green LED indicates normal equipment
Indication
condition. (Troubleshooting with the green LED)
The LED A of the outdoor unit indicate microcomputer operation condition.
Even after the error is cancelled and the equipment operates in normal condition, the LED
indication remains.
Service Diagnosis
Operation stops and operation lamp blinks only for indoor unit which the different operation
Caution for Diagnosis