SiBE12-933_A
1.3

Floor / Ceiling Suspended Dual Type

Connectors
PCB (1) (Control PCB)
1) S6
2) S7
3) S21
4) S24
5) S26
6) S32
7) S37
PCB (2) (Power Supply PCB)
1) S36
PCB (3) (Display PCB)
1) S25
PCB (4) (Signal Receiver PCB)
1) S27
2) S31
Note:
Other designations
PCB (1) (Control PCB)
1) JA
2) SW2
3) LED A
PCB (2) (Power Supply PCB)
1) V1
1) FU1
PCB (3) (Display PCB)
1) LED1
2) LED2
3) LED3
PCB (4) (Signal Receiver PCB)
1) SW1 (S1W)
Printed Circuit Board Connector Wiring Diagram
Connector for swing motor (horizontal swing)
Connector for AC fan motor
Connector for centralized control
Connector for display PCB
Connector for signal receiver PCB
Connector for heat exchanger thermistor
Connector for power supply PCB
Connector for control PCB
Connector for control PCB
Connector for control PCB
Connector for room temperature thermistor
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function
Refer to page 255 for detail.
Select switch ceiling or floor
LED for service monitor (green)
Varistor
Fuse (3.15A)
LED for HOME LEAVE operation (red)
LED for timer (yellow)
LED for operation (green)
Forced cooling operation ON/OFF switch
Printed Circuit Board Connector Wiring Diagram