Removal Of The Electrical Box - Daikin G-Series Service Manual

Inverter multi for 2 rooms
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

Outdoor Unit
1.2

Removal of the Electrical Box

Procedure
Step
1. Disconnect the
connecting wires
Remove the 2
1
grounding screws.
Remove the 2 screws
to remove the wiring
fixture.
Then remove the all
screws for the
connectors to
disconnect the power
supply cable and the
connecting wires.
2. Remove the electrical box
1
Release the outdoor air
thermistor from the
holder.
Lift up the guard net to
2
remove.
228
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Room A
4
4
P
Wiring
fixture
Outdoor air thermistor
Guard net
Guard net
Fasten the wires with screws
on the terminal board.
The terminal board is united
Room B
resin formation.
Power supply
Grounding
screws
(R7573)
(R7208)
(R7209)
SiBE12-933_A
Points
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading