Printed Circuit Board Connector Wiring Diagram; Wall Mounted Type - Daikin G-Series Service Manual

Inverter multi for 2 rooms
Hide thumbs Also See for G-Series:
Table of Contents

Advertisement

Printed Circuit Board Connector Wiring Diagram

1. Printed Circuit Board Connector Wiring Diagram

1.1

Wall Mounted Type

1.1.1 ATX20-35G
Connectors
PCB (1) (Control PCB)
1) S6
2) S26
3) S32
4) S200
5) S403
PCB (2) (Display PCB)
1) S27
Note:
Other designations
PCB (1) (Control PCB)
1) V1
2) JA
3) LED A
4) FU1 (F1U)
PCB (2) (Display PCB)
1) SW1 (S1W)
2) LED1
3) LED2
4) RTH1 (R1T)
36
Connector for swing motor (horizontal blades)
Connector for display PCB
Connector for heat exchanger thermistor
Connector for fan motor
Connector for adaptor for wired remote controller (optional accessory)
Connector for control PCB
Varistor
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function (auto-restart)
Refer to page 255 for detail.
LED for service monitor (green)
Fuse (3.15A)
Forced cooling operation ON / OFF switch
LED for operation (green)
LED for timer (yellow)
Room temperature thermistor
Printed Circuit Board Connector Wiring Diagram