[M] Damp heater
(TWD/SAD/ASD/AUD/CND models)
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
2. Remove original glass. (See Fig. 7-8-6)
3. Move carriage 1 to around the center.
(See Fig. 7-8-22)
4. Remove the screw, release the hook, and de-
tach the damp heater plate.
5. Release 2 clamps and detach the connector.
6. Remove 2 screws and remove damp heater.
1600/2000/2500 SCANNER
Screw
065-9
Damp heater
Screw
7 - 34
Damp heater plate
Hook
Fig. 7-8-38
Screw
Connector
Clamp
Fig. 7-8-39