Connecting A 1500 Series Power Injector - Cisco Aironet 1550 Series Hardware Installation Manual

Outdoor mesh access point
Hide thumbs Also See for Aironet 1550 Series:
Table of Contents

Advertisement

Powering the Access Point
Powering the Access Point
The access point can be powered by one of these methods:
In all cases above, the AC branch circuit powering the access point must be limited to no more than 20A
Note
from the over-protection device supplied by the user. This branch power protection must meet all local
and national electrical codes.

Connecting a 1500 Series Power Injector

The power injector provides 56 VDC to the access point over the Ethernet cable and supports a total
end-to-end Ethernet cable length of 100 m (328 ft) from the switch to the access point.
The cable from the power injector to the access point and/or switch should be at least 10 ft (3.05 m) long.
Note
The PoE-Out port is disabled when the access point is powered by the power injector.
Note
When your access point is powered by an optional power injector, follow these steps to complete the
installation:
Step 1
Before applying PoE to the access point, ensure that the access point is grounded (see the
the Access Point" section on page
Review
Step 2
Note
Connect a CAT5e or better Ethernet cable from your wired LAN network to the power injector.
Step 3
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. Statement 1023
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
2-44
PoE—56 VDC; for 1552E/1552H access points
Connecting a 1500 Series Power Injector, page 2-44
AC power
110 to 240 VAC for a 1552I access
110 to 480 VAC for 1552E/1552H access
120
VAC—Connecting an AC Power Cable to the Access Point, page 2-53
External 12 VDC
Connecting a DC Power Cable to the Access Point, page 2-54
POC—40 to 90 VAC (Quasi-AC); only for a 1552C access point
Connecting a Cable POC Power to the Access Point, page 2-57
Figure 2-2
to identify the components needed for the installation.
The 1550 power injector can only be used in an indoor environment, therefore, the cable from
the injector must travel from the protected location to the outside mounted access point.
point—Connecting Streetlight AC Power, page 2-50
points—Connecting Streetlight AC Power, page 2-50
2-40.
Chapter 2
Installing the Access Point
"Grounding