Chapter 2
Installing the Access Point
Use a Phillips screw driver to loosen the pin capture screw, but be careful not to remove it.
Step 5
Cut the cable stinger connector pin (see
Step 6
Figure 2-43
1
Insert the cable stinger connector pin into the cable POC connector opening in the access point case.
Step 7
Screw the F-connector adapter into the POC connector opening, and hand-tighten.
Step 8
Step 9
Use an adjustable wrench to tighten the F-connector adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 10
Use a Phillips screw driver to tighten the F-connector adapter pin capture screw on the RF splitter to 5.5
to 6.0 in. lbs (0.62 to 0.67 Nm).
Step 11
Before connecting cable POC power to the access point, ensure that the antennas are attached to the
access point.
Connect or attach the cable company POC cable to the F-connector adapter according to their
Step 12
specifications.
Turn on cable POC power.
Step 13
Reinsert the RF splitter shunt.
Step 14
Check the cable modem Power and Cable LEDs and verify that the cable modem receives power and
Step 15
registers to the cable network.
The Power LED (fifth LED from the hinge) is green to indicate power is available.The Cable LED
(second LED from the hinge) should be blinking green to indicate scanning the cable network and green
to indicate registered on the cable network.
Step 16
Replace the ATTN and SHUNT connector plugs on the top of the access point and tighten to 6 to 7 ft lbs
(8.1 to 9.5 Nm).

Installing the Access Point in Hazardous Locations

This section describes the steps required to retrofit the 1552H access point and prepare it for installation
in Class I, Division 2, Zone 2 hazardous locations.
OL-24247-01
Cable Stinger Connector Pin
Pin length is 0.75 + 0.1inch (1.91 + 0.25 cm).