Step 4 - Mark And Trim High Voltage Isolator; Step 5 - Install Ac Mains Power Outlets - AMX HPX-1600 Installation Manual

Retractable connection port and hpx modules
Table of Contents

Advertisement

Step 4 - Mark and Trim High Voltage Isolator

1.
Position the High Voltage Isolator so that the partition created by the top folded tabs falls between the last
low-voltage, secondary-circuit module and the first AC Mains Power Outlet.
2.
Mark the High Voltage Isolator at the point it exits the aluminum chassis.
3.
Remove the High Voltage Isolator and trim the paper so that it will be flush with the bottom of the chassis
upon final installation.
As an additional reference, use the template provided in FIG. 32 to trim the High Voltage Isolator to the proper
length based on the number and type of AC Mains Power Modules installed.
FIG. 32
High Voltage Isolator - Trim Template
The template assumes that no Stop-Block (HPX-AC-SB) is used. The template is for
reference only. Verify that the High Voltage Insulation paper is flush with the bottom of
the aluminum chassis upon final assembly.

Step 5 - Install AC Mains Power Outlets

Reinstall the trimmed High Voltage Isolator, trapping the low-voltage, secondary-circuit cables on the sides of
the unit as before. Install the AC Mains Power Outlets, Circuit Breaker Modules and Blank Panel Modules
(Including Product Label Panels) as required.
Continue with the HPX-1600 installation as described in the accompanying Installation Guide.
HPX-1600 Retractable Connection Port
HPX-PA-HVI High Voltage Isolator
33

Advertisement