HPX-PA-HVI High Voltage Isolator
Overview
The HPX-PA-HVI High Voltage Isolator (FG559-33) is designed to be installed in the HPX-1600-xx-xx
Hydraport Retractable Connection Port to separate the AC Mains Power from low-voltage, secondary-circuits
(FIG. 29).
FIG. 29
HPX-PA-HVI (Folded for Installation)
If AC Mains Power Outlets are to be used in the HPX-1600 this item must be
installed in order to maintain Product Safety Certifications. Failure to install
this item properly may void Product Safety Certifications.
Product Specifications
HPX-PA-HVI Specifications
Material:
Thickness:
Dielectric Strength:
Included Accessories:
Installation
Only a professional, AMX-qualified installer should perform this installation.
Installation must conform to all local codes. This product may not be installed
by the end-user.
Tools Required
HPX-1600 Retractable Connection Port
Vulcanex ®, Vulcanized Fiber
0.4mm (0.016in)
300V/mil (4,800V)
Installation Guide
Scissors
HPX-PA-HVI High Voltage Isolator
31