Step 4 - Insert The Modules - AMX HPX-1600 Installation Manual

Retractable connection port and hpx modules
Table of Contents

Advertisement

Installing the HPX-1600

Step 4 - Insert the Modules

See Step 4.6 for the installation of High Voltage Isolators (HPX-PA-HVI) These
Isolators must be installed properly to maintain product safety certifications.
All Low-Voltage, Secondary-Circuit (LVSC) Modules must be installed above the AC
Power Outlets and Circuit Breaker Modules in the HPX-1600 Base Assembly. The
LVSC Modules will therefor be installed first.
1.
Latch the system in the closed (down) position.
2.
Place the HPX-1600 Base assembly upside down on a suitable surface to ensure the top cover is not
scratched.
3.
Remove the four Mounting Screws that secure the Bottom Cover to the aluminum frame, and remove the
bottom cover. (FIG. 9).
FIG. 9
Installing the Bottom Cover
4.
Slide the pre-terminate modules one at a time into the Base assembly.
Note the orientation of each module: a small tab exists on the bottom side (shown facing up in FIG. 10) of
the faceplate of each module. Ensure this tab is facing the bottom side of the system (see FIG. 11 on
page 14).
12
Bottom Cover
(4) mounting screws
HPX-1600 Retractable Connection Port

Advertisement

Table of Contents
loading