Kipor Sinamaster I G2600 Operation Manual page 10

Sinemaster digital inverter generator
Table of Contents

Advertisement

Parallel
receptacle
The parallel cabinet can be connected with the parallel socket when the generator
set needs a increasing of parallel output power.
Smart throttle
Engine speed is kept at idle automatically when the electrical appliance is
disconnected and it returns to the proper speed to power of the electrical load
when electrical appliance is connected. This position is recommended to minimize
the fuel consumption while in operation.
WARNING
Smart throttle system does not operate effectively, if the electrical appliance
requires big momentary electric power.
When high electrical loads are connected simultaneously, turn the Smart-
throttle switch to the OFF position to reduce voltage vibration.
In DC operation, turn the Smart-throttle switch to the OFF position.
OFF:
Note:Smart throttle system does not operate. Engine speed is kept over rated speed.
Smart Throttle Switch
10.TROUBLESHOOTING
When the engine will not start:
NO
Is there fuel in the tank?
YES
NO
Is the engine switch on?
YES
NO
Is there enough oil in the engine?
YES
NO
Is there a spark from
Replace the
the spark plug?
spark plug.
W A R N I N G
Be sure there is no spilled
fuel around the spark pulg.
Spilled fuel may ignite.
Is the fuel reaching the
carburetor.
If the engine still does not
start, take the generator to
an authorized dealer.
Refill the fuel tank.
Turn the engine switch on.
Add the recommended oil.
Still no
Take the generator to an
spark
authorized dealer.
To check:
1)Remove the spark plug cap and clean
any dirt from around the spark plug.
2)Remove the spark plug and install the
spark plug in the plug cap.
3)Set the plug side electrode on the cylin-
der head to ground.
4)Pull the recoil starter, sparks should jump
across the gap.