Battery Replacement And Disposal; Fiber Optic Ports-Optical Safety - Extreme Networks BlackDiamond 8806 Hardware Installation Manual

Hide thumbs Also See for BlackDiamond 8806:
Table of Contents

Advertisement

Black Diamond SSI DC PSU, Model 60021:
The wire must be UL Listed Type TC (Tray Cable), three conductor, 8 AWG, jacketed, and marked
(UL) TC, 90C min.
NOTE
Tray Cable is a UL requirement only in the USA. Outside the United States, standard 8 AWG
2
(8.35mm
), 90C wire is acceptable.
There is no wall plug; 3-conductor wires have been stripped and are ready for connection to DC
power source mains.
The device connector is a Molex Shell Connector PN 42816-0312; Molex Pin Connectors PN
42815-0032.
The assembly rating is 75VDC, 30A, (Do not disconnect under load).
NOTE
This equipment is not intended to be directly powered by power distribution systems where
phase-phase voltages exceed 240V AC (2P+PE), such as those used in Norway, France, and other countries.
For these applications it is recommended that a transformer be used to step down the voltage to < 240V AC
from phase-phase, or that you make a connection to a (P+N+PE) power distribution where voltages do not
exceed 240V AC.
All installations should confirm that the product is reliably grounded according to the country's local electrical codes.

Battery Replacement and Disposal

Batteries included with Extreme products are encapsulated and must be replaced only by qualified
Extreme Service personnel. Contact your Extreme Networks Service personnel for product replacement.
Do not attempt to replace the battery. If these instructions are disregarded and replacement of these
batteries is attempted, the following guidelines must be followed to avoid danger of explosion:
Replace with the same or equivalent battery type as recommended by the battery manufacturer.
Dispose of the battery in accordance with the battery manufacturer's recommendation.
Fiber Optic Ports—Optical Safety
The following safety warnings apply to all optical devices used in Extreme Networks equipment that
are removable or directly installed in an I/O module or chassis system. Such devices include but are not
limited to gigabit interface converters (GBICs), small form factor pluggable (SFP) modules (or
mini-GBICs), XENPAK transceivers, and XFP laser optic modules.