Configuring Radio Settings

Configuring Radio Transmit Power

Beginning in privileged EXEC mode, follow these steps to set the transmit power on your access point
radio:
Command
Step 1
configure terminal
Step 2
interface dot11radio 0
Step 3
power local
{ 1 | 5 | 20 | 30 | 50 | 100 | maximum }
Step 4
end
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Use the no form of the power command to return the power setting to maximum, the default setting.

Limiting the Power Level for Associated Client Devices

You can also limit the power level on client devices that associate to the access point. When a client
device associates to the access point, the access point sends the maximum power level setting to the
client.
Beginning in privileged EXEC mode, follow these steps to specify a maximum allowed power setting on
all client devices that associate to the access point:
Command
Step 1
configure terminal
Step 2
interface dot11radio 0
Step 3
power client
{ 1 | 5 | 20 | 30 | 50 | 100 }
Step 4
end
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Use the no form of the client power command to disable the maximum power level for associated clients.
Aironet extensions must be enabled to limit the power level on associated client devices. Aironet
Note
extensions are enabled by default.
OL-2851-01
Purpose
Enter global configuration mode.
Enter interface configuration mode for the radio interface.
Set the transmit power to one of the power levels allowed in
your regulatory domain. All settings are in mW.
The settings allowed in your regulatory domain might
Note
differ from the settings listed here.
Return to privileged EXEC mode.
Purpose
Enter global configuration mode.
Enter interface configuration mode for the radio interface.
Set the maximum power level allowed on client devices that
associate to the access point. All settings are in mW.
The settings allowed in your regulatory domain might
Note
differ from the settings listed here.
Return to privileged EXEC mode.
Cisco Aironet 1100 Series Access Point Installation and Configuration Guide

Configuring Radio Transmit Power

7-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents