Fire-Lite MS-9200UD User Manual page 13

Fire alarm control panel
Hide thumbs Also See for MS-9200UD:
Table of Contents

Advertisement

)HDWXUHV DQG 2SWLRQV
068' 31 $ 
EIA-232 Printer/PC interface (variable baud rate)
80-character LCD display (backlit)
Real-time clock/calendar with daylight savings time control
History file with 1,000 event capacity
Advanced fire technology features:
✓ Automatic drift compensation
✓ Maintenance alert
✓ Detector sensitivity test capability (NFPA 72 compliant)
✓ Automatic device type-code verification
✓ Point trouble identification
Waterflow selection per module point
Alarm verification selection per detector point
Walktest, silent or audible
PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
Silence inhibit timer option per NAC
Autosilence timer option per NAC
Continuous, March Time, Temporal or California code for main circuit board
NACs with two-stage capability
Selectable strobe synchronization per NAC
Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules,
AFM annunciators or LCD-80F Remote annunciator
Auto-program (learn mode) reduces installation time. Reports two devices set to
the same address
Password and key-protected nonvolatile memory
User programmable password
Fully programmable from local keypad or optional keyboard
Upload/Download (local or remote) of program and data via integral DACT
SLC operates up to 10,000 ft. (3,000 m) with twisted, shielded wire or 3,000 ft
(900 m) with untwisted, unshielded wire
Compatible with Fire•Lite's newer series devices
✓ CP350, CP355: addressable Ionization Smoke Detector
✓ SD350(T), SD355(T), AD355: addressable Photo Smoke Detector (T= with
Thermal Sensor)
✓ H350(R), H355(R), H355HT: Fast Response Heat Detector (R=Rate-of-Rise
option, HT=High Temperature 190
✓ D350P(R): addressable Photo Duct Detector (R=alarm relay option)
✓ B501BH & B501BHT Sounder Base
✓ B224RB Relay Base
✓ B224BI Isolator Base
✓ MMF-300: Monitor Module
✓ MMF-300-10: Monitor Module (10 Input Class B or 5 Input Class A)
✓ MDF-300: Dual Monitor Module (uses two consecutive SLC addresses)
✓ MMF-301: Miniature Monitor Module
✓ MMF-302: 2-wire Detector Module
✓ MMF-302-6: 2-wire Detector Module (6 Input Class B or 3 Input Class A)
✓ CMF-300: Control Module
✓ CMF-300-6: Control Module (6 Output Class B or 3 Output Class A)
✓ CRF-300: Relay Module
✓ CRF-300-6: Relay Module (6 Form-C relays)
✓ BG-12LX: Manual Pull Station
✓ I300: Isolator Module