Device Overview - Omicron Lab OTMC 100 User Manual

Omicron lab antenna-integrated ptp grandmaster clocks
Hide thumbs Also See for OTMC 100:
Table of Contents

Advertisement

OTMC 100 Series User Manual
3

Device Overview

Membrane vent covering the pushbutton
(tightening torque: 0.6 - 0.8 Nm)
2 threaded holes
M6 x 9 mm
for clamping block
36 mm
Type plate with
product name
and serial number
The OTMC 100 does not provide an ON/OFF switch! The device automatically powers up after supply
voltage is provided via Ethernet (PoE).
The LED indicates the device status:
LED continuously off
LED lights red
LED flashes red
LED lights orange
LED flashes green
12
Threaded hole
1/4" BSW x 6.5 mm
for temporary mounting
on a stand
106.2 mm
LED
Waterproof RJ45 connector
acc. to IEC 61076-3-106,
variant 4
The OTMC 100 is not supplied with power via the RJ45 Ethernet
connector.
Device reboot is in progress.
Software update is in progress.
ATTENTION: Do not disconnect the OTMC 100 from its PoE source
(Ethernet network) during a software update!
Intermediate state when entering the recovery mode manually or
when initiating a factory reset (see also "Operating Procedures
Performed Directly on the Device" on page 31).
The OTMC 100 is in the recovery mode, waiting for new software. In
the recovery mode, the device provides only a rudimentary Web
Interface just allowing for the upload of a software image (see also
"Operating Procedures Performed Directly on the
Device" on page 31).
Weight: < 500 g
Degree of protection:
IP65 (for outdoor use) if the waterproof
RJ45 connector is inserted properly
Protective cap
14.5 mm
Ø 115.5 mm
Base plate