Omicron Lab OTMC 100 User Manual page 63

Omicron lab antenna-integrated ptp grandmaster clocks
Hide thumbs Also See for OTMC 100:
Table of Contents

Advertisement

Insecure HTTP enabled
In order to deactivate an existing password protection, just deselect the Web Interface
authentication enabled check box, and click the Change button to apply your settings to
the OTMC 100. Attention: If you select the checkbox again, the OTMC 100 will automatically
use the last valid password defined. Therefore, make sure to keep your password stored at a
save place for future use even if you deactivate password protection.
Perform a factory reset on the device if you forgot your password (see "6.2 Operating
Procedures Performed Directly on the Device" on page 31). This will reset the OTMC 100 to
the default password timeserver.
7.3.2.2 Generate Certificate tab
When accessing the OTMC 100 via HTTPS, an "untrusted connection" message will appear because
the OTMC 100 does not have a valid certificate.
To avoid such messages, it is necessary to provide the OTMC 100 with such a certificate. There are
two possible ways: Generating a certificate signed by an accredited certification authority or
generating a certificate signed by yourself.
Web browsers usually contain the digital signatures of all accredited certification authorities by default
and will therefore accept certificates signed by those authorities. However, when using a self-signed
certificate, the web browser will not recognize you as a valid certification authority (since it does not
know the signature of "your" certification authority) and thus not accept such certificates. This behavior
If this check box is selected, the OTMC 100 can be accessed via
the HTTP protocol. If deselected, access is only possible via the
secure HTTPS protocol.
The OTMC 100 Web Interface
63