6.2.2

Performing a Factory Reset (Reset to Factory Defaults)

A factory reset can also be performed via the Web Interface (see "Performing a factory
reset" on page 29). Resetting the device to the factory defaults may be necessary if you
forgot your password, for example.
1. Press the pushbutton and keep it pressed.
2. The LED goes off.
3. After approx. 5 s, the LED lights up orange. Keep the button pressed and wait until the LED lights
up red.
4. Release the pushbutton.
5. After approx. 15 s the LED changes to green to indicate operational readiness.
6. The device now has the factory default configuration settings.
6.2.3
Entering the Recovery Mode Manually (and Uploading New Software to
the OTMC 100)
Entering the recovery mode manually is not necessary under normal circumstances since the recovery
mode is entered automatically if a software update performed via the Web Interface fails.
1. Press the pushbutton and keep it pressed.
2. The LED goes off for approx. 5 s.
3. Release the pushbutton as soon as the LED lights up orange.
4. After approx. 20 s the LED flashes green to indicate the recovery mode.
5. Open the OMICRON Device Browser and right-click the OTMC 100 (see "Accessing the
OTMC 100 from a Computer" on page 21). Select the Upgrade Device option from the context
menu. The device provides a rudimentary Web Interface allowing for an upload of a software
image.