OTMC 100 Series User Manual
Operation mode (cont.)
User description
PTP management interface
enabled
7.3.3.2 Default Settings tab
Priority 1
Priority 2
68
One step is the recommended mode since this mode produces less
network traffic. The two step mode should only be used if some
equipment used in the network does not work correctly with the one
step mode.
Enter a description for the OTMC 100. This may be required to
identify the OTMC 100 uniquely if you are using more than one
OTMC 100 devices in the network.
Select the check box to enable access via the PTP management
interface.
Use this field to specify the priority values. To each PTP master
clock, two priority values (Priority 1 and Priority 2) may be assigned
by the user. If more than one PTP grandmaster clock is available in
the network, a clock with a lower Priority 1 value will always be a
preferred master clock over a clock with a higher Priority 1 value
(see IEEE 1588-2008, clause 6.6.2.3). A value in the range from 0
to 255 may be assigned to the Priority 1 parameter (see
IEEE 1588-2008, clause 7.6.2.2).
...