Digital Out Adv; Working With Spdif Devices; Working With Aes/Ebu Devices - SoundCraft RM1ds User Manual

Digital radio console
Table of Contents

Advertisement

RM1d/RM1ds User Guide

Digital out adv. . . . .

Digital out adv
Digital out adv
Digital out adv
Digital out adv
The settings found in this menu are for configuring the Status Bits of the SPDIF and AES/EBU
outputs. In most applications the default settings for these outputs are used, but in certain
circumstances it may be necessary to make manual adjustments.
The table below shows the options available for each output.

Working with SPDIF Devices

When the RM1d is synchronised to an external Word Clock source, most digital devices connected
to the RM1d's SPDIF digital outputs will happily synchronise to the Word Clock being sent from
the RM1d via the SPDIF digital output.
In most applications the SPDIF digital output can be set to 'Auto' configure in the DIGITAL OUT
ADV. Setup Menu.
In the uncommon event that a receiving device connected to the RM1d's SPDIF digital output is
not synchronising correctly it may be necessary to manually configure the Status Bits for the
SPDIF output.
This will normally involve setting the Sample Rate Flag (Fs) to the same Word Clock setting that
the RM1d is receiving and setting the Word Length (WL) to match that of the device connected
to the RM1d's SPDIF digital output.
The Pro Flag (Pro) setting would normally be set to 'Consumer' (CON) but could be switched to
'Professional' (PRO) if the CON setting does not work correctly.

Working with AES/EBU Devices

When the RM1d is synchronised to an external Word Clock source, most digital devices connected
to the RM1d's AES/EBU digital outputs will happily synchronise to the Word Clock being sent
from the RM1d via the AES/EBU digital output.
In most applications the AES/EBU digital output can be set to 'Auto' configure in the DIGITAL
OUT ADV. Setup Menu.
In the uncommon event that a receiving device connected to the RM1d's AES/EBU digital
output is not synchronising correctly it may be necessary to manually configure the Status Bits
for the AES/EBU digital output.
This will normally involve setting the Sample Rate Flag (Fs) to the same Word Clock setting that
the RM1d is receiving and setting the Word Length (WL) to match that of the device connected
to the RM1d's AES/EBU digital output.
The Pro Flag (Pro) setting would normally be set to 'Professional' (PRO).