Network Connections; Bc-8060 Network Connectors; Network Cabling - Datalogic PowerScan M8500 Product Reference Manual

Datalogic powerscan industrial handheld area imager bar code reader with datalogic’s star cordless system
Hide thumbs Also See for PowerScan M8500:
Table of Contents

Advertisement

PowerScan M8500 Setup

Network Connections

BC-8060 Network Connectors

The multidrop network is a bus system which is propagated from one BC-8060 cradle to
another using individual cables. This is possible thanks to the RS-485 connector on the
front panel of the cradle.
Figure 10. Network Connectors
All cradles are connected together within the bus system through the Datalogic RS-485
splitter cable (CAB-428, part number 90A051950), which must be inserted in the RS-485
cradle connector.
Cable length should be kept to a minimum, as with all bus systems.

Network Cabling

The Multidrop line is made using RJ45 connectors and a cable having the following
specifications:
Pin
1
2
3
4
5
6
7
8
26
twisted pair AWG 24 wires
120  impedance
maximum network cable length 1200 meters
Function
RS-485 +
RS-485 -
N.C.
VDC –
VDC –
N.C.
VDC +
VDC +
RJ45
VDC-
5
RS-485-
2
RS-485+
1
Twisted Pair – RS-485 bus
Twisted Pair - Power supply
RJ45
RJ45
VDC+
5
8
VDC-
2
5
RS-485-
1
2
RS-485+
1
Twisted Pair – RS-485 bus
RJ45
8
5
2
1
PowerScan® M8500