MATRIX-1000™ QUICK GUIDE Figure A Good Read LED Reading Window Auxiliary Interface External Trigger LED Main/Auxiliary Interface Power On LED Main Tx LED For further details on product installation, see the complete Installation Manual available on the CD included with this product. NOTE Compliance: - This product is intended to be installed by Qualified Personnel only.
Page 3
MATRIX-1000™ QUICK GUIDE ELECTRICAL FEATURES Power Supply Voltage 10 to 30 Vdc Power Consumption 4 W max.; 2.5 W typical Communication Interfaces Main - RS485 half-duplex 2400 to 115200 bit/s Auxiliary - RS232 2400 to 115200 bit/s Input External Trigger Opto-coupled and polarity insensitive Output OUT3...
Page 4
MATRIX-1000™ QUICK GUIDE READING FEATURES Frame Rate up to 30 frames / sec Pitch 10° - 35° Readable Codes up to100 per Frame Tilt 0° - 360° Focus Typ. Linear Typ. 2D Code Reading Distance Distance and Stacked Resolution mm (in) Field of View MODELS Code...
Page 5
MATRIX-1000™ QUICK GUIDE Electrical Connections: The Matrix-1000™ reader provides a 25-pin male D-sub connector for connection to power supply, Host interface (Main and Auxiliary), and input/output signals. 25-pin male D-Sub Connector 25-pin male D-sub connector pinout Name Function SHIELD Cable shield internally connected by capacitor to the chassis RTX485+ RX or TX data of RS485 Half Duplex Main Interface - positive pin RTX485-...
Page 6
MATRIX-1000™ QUICK GUIDE User Interface: RS232 PC-side connections 9-pin male connector 25-pin male connector Name Name How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections.
Page 7
MATRIX-1000™ QUICK GUIDE C-BOX 100 pinout for Matrix-1000™: The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the Matrix- 1000™ reader is connected by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Power 1, 3, 5 2, 4, 6...
Page 8
MATRIX-1000™ QUICK GUIDE Input / Output Connections: Input Vext MATRIX MATRIX USER INTERFACE USER INTERFACE 30 Vdc Max. Input PNP command using external power Input PNP command using Matrix-1000™ power MATRIX MATRIX USER INTERFACE USER INTERFACE Vext 30 Vdc Max. Input NPN command using external power Input NPN command using Matrix-1000™...
Page 11
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el MATRIX-1XXX e tutti i suoi modelli and all its models et tous ses modèles...