19
Specifications for each machine setting file type
Account track data setting file:
- Begin the file with #EKC_TAB.
- Max. 1,000 files can be edited.
- A line should include PASSWORD, NAME, and LIMIT, separated by a tab.
- Use up to 8 digits numbers (0 - 9) and alphabets only to specify
PASSWORD.
- Use numbers and alphabets only to specify NAME.
- Use up to 8 digits numbers (0 - 9) only to specify LIMIT (0 – 99,999,999).
E-mail data setting file:
- Begin the file with #IP_EMAIL.
- A line should include NAME, ADDRESS, REFERENCE, and DAILY,
separated by a tab.
- NAME should be 24 bytes or less.
- ADDRESS should be 250 bytes or less.
- REFERENCE should be 250 bytes or less.
- Mark DAILY USE with "1" or DAILY NOT USE with "0" in each column.
HDD data setting file:
- Begin the file name with #IP_HDD.
- A line should include NAME, NUMBER, REFERENCE, or DAILY,
separated by a tab.
- NAME should be 24 bytes or less.
- Use up to 9 digits numbers (0 - 9) only to specify a NUMBER.
- REFERENCE should be 24 bytes or less.
- Mark DAILY USE with "1" or DAILY NOT USE with "0" in each column.
FTP data setting file:
- Begin the file name with #IP_FTP.
- A line should include NAME, ADDRESS, PORT, FILEPATH, LOGINNAME,
PASSWORD, REFERENCE, or DAILY being separated by a tab.
- NAME should be 24 bytes or less.
- ADDRESS should be 63 bytes or less.
- Use up to 5 digits numbers (0 - 9) only to specify PORT (1 – 65,535).
- FILEPATH should be 96 bytes or less.
- LOGINNAME should be 47 bytes or less.
- PASSWORD should be 24 bytes or less.
- REFERENCE should be 24 bytes or less.
- Mark DAILY USE with "1" or DAILY NOT USE with "0" in each column.