CONTROL BOARD INSTALLATION

DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER CONTROL BOARD) IN PLACE.
WARNING
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
NOTE
Your components may look slightly different than ones shown
1.
Place control board in firebox, aligning holes in control board with
holes in firebox bottom. MAKE SURE SEALING GASKET IS IN
PLACE ON FIREBOX BOTTOM! Secure to firebox bottom with
(6) screws previously removed.
2.
Install log grate/burner heat shield assembly into fireplace, ensure
entire assembly (front flange) is inside firebox when completed.
3.
Reinstall front log supports, securing with screws previously
removed.
4.
Reinstall burner tube, sliding venturi over control board orifice,
placing mounting holes in burner tube over tabs on log grate/
burner heat shield assembly.
LP Gas Models: Reinstall LP log plate.
5.
Reinstall pilot shield.
6.
Reinstall refractory panels, if previously removed.
7.
Reinstall bottom refractory panels.
8.
Reinstall log set.
9.
Reconnect gas line to manual shut-off valve.
10. Reconnect
any
wall
thermostat wires to top & bottom terminals on gas valve or
re-connect all wiring harnesses to gas valve. Plug all components
into electrical outlet.
11. Reinstall glass frame assembly.
12. R e i n s t a l l u p p e r l o u ve r , u p p e r h o o d a n d l o we r gr i l l .
13. Turn gas on.
14. Verify proper log placement, operation of fireplace, and any
electrical components.
CAUTION
CHECK ALL CONNECTIONS FOR LEAKS, WHETHER FIELD OR FACTORY MADE.