NON-COMBUSTIBLE ZONE:
Rigid pipe: 1-1/2" (38mm) above elbow for entire width and depth (behind header) of fireplace.
#700-1 Series Flexible Venting: 1" (25mm) above elbow for entire width and depth (behind header) of fireplace.
14"(356mm)
12"(305mm)
14"
12"
10"
356mm
305mm
254mm
203mm
Figure 11a
TO PREVENT GLASS FRAME ASSEMBLY FROM FALLING FROM FIREPLACE AND BECOMING DAMAGED, FOLLOW THESE
CAUTION
INSTRUCTIONS EXACTLY WHEN REMOVING AND INSTALLING GLASS FRAME ASSEMBLY
REMOVE GLASS FRAME ASSEMBLY
1.
Locate spring-loaded handles securing glass frame assembly at top & bottom of firebox.
2.
Pull bottom handles out and down to release glass frame assembly bottom.
3.
Pull top handles out and up to release glass frame assembly top.
4.
Remove glass frame assembly from fireplace.
INSTALL GLASS FRAME ASSEMBLY
1.
Place glass frame assembly onto fireplace front.
2.
Pull top handles out and down to secure glass frame assembly top.
3.
Pull bottom handles out and up to secure glass frame assembly bottom.
Pull latches out and up to release glass frame
assembly top.
Pull latches out and down to attach glass frame
assembly top.
Pull latches out and down to release glass frame
assembly bottom.
Pull latches out and up to attach glass frame
assembly bottom.
Figure 11b
MANTEL REQUIREMENTS
3
"
10" (254mm)
4
19mm
8" (203mm)
8"
6"
152mm
GLASS FRAME ASSEMBLY
11