kozy heat 56701 Installation Manual page 20

Direct vent gas fireplace
Table of Contents

Advertisement

#700-1 SERIES DIRECT VENT TERMINATION KIT(S) INSTALLATION
The flex pipe is permanently attached to the exterior plate. DO NOT ATTACH #745-1 or #718-1 termination kit to fireplace
IMPORTANT
(or extension kit) until it has passed through the wall. Install termination plates to outside wall exterior.
HORIZONTAL TERMINATIONS Refer to illustration on following page.
IF TERMINATING AGAINST VINYL SIDING, A VINYL SIDING PROTECTOR, INCLUDED WITH #718-1 AND #745-1 DIRECT
VENT KITS, MUST BE USED. FOLLOW INSTRUCTIONS INCLUDED.
Horizontal Top Vent Terminations using Kozy Heat #700-1 series Flexible Vent System must install #923-F Kozy Heat Flex
ATTENTION
Vent System Adaptor.
CAUTION
This gas appliance must not be connected to a chimney flu serving another type of appliance.
Page 15 has information on restrictor installation in conjunction with venting installation. Page 28 has information on restrictor
NOTE
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
1.
If your vent system application does not require an extension kit, proceed to step #7.
2.
If your vent system application will require one or more extension kits (Part #746-1), proceed with following steps. Each #746-1
extension kit contains enough 4" & 7" flexible aluminum to extend chimney an additional 6ft. (1.83m).
3.
Gently stretch 4" & 7" flexible aluminum pipes on termination kit (#745-1 or #718-1) and on each extension kit (if used) length
required for installation.
DO NOT STRETCH EXTENSION KIT- #746 BEYOND 6ft. (1.83m). DO NOT STRETCH BEYOND WHAT IS REQUIRED - IT IS VERY
IMPORTANT
DIFFICULT TO RECOMPRESS FLEX PIPES ONCE STRETCHED.
4.
Place a bead of sealant outside 4" flex pipe collar (C) (end with EXTERNAL lip), sliding it inside 4" pipe on top of fireplace (D).
Secure with 3 evenly spaced screws.
5.
Place a bead of sealant inside 7" flex pipe collar (E) (end with INTERNAL lip), sliding it over 7" pipe on top of fireplace (F). Secure
with 3 evenly spaced screws.
6.
If additional extension kits are required, repeat steps #4 - #5, placing 4" & 7" pipes onto previous extension kit.
OPTIONAL: Place insulation between 7" pipe and wall studs.
7.
With spacer legs toward wall, slide interior firestop (H) over 7" pipe and attach to interior wall (over wall materials).
Attachment brackets are included with termination kit. These optional brackets should be screwed or nailed (not provided)
NOTE
onto top and bottom of 9-1/2" (241mm) H x 9-1/2" (241mm) W opening on exterior of house. The termination plates then fit
between these brackets. Using screws provided, secure brackets to termination box (A). Attach vinyl siding protector (G).
8.
Apply a liberal bead of exterior sealant around outer edge of termination box (A), placing assembly through opening in exterior wall.
Place screws through four slots (B), securing it in place.
9.
Gently pull 4" & 7" pipes down to top of extension kit, or top of fireplace if no extension kits were used.
10. Place a bead of sealant outside 4" flex pipe collar (C) and slide it into 4" pipe on extension kit or top of fireplace (D).
Secure with 3 evenly spaced screws.
11.
Place a bead of sealant inside 7" flex pipe collar (E) and slide it over 7" pipe on extension kit or top of fireplace (F). Secure with 3
evenly spaced screws.
ILLUSTRATION ON FOLLOWING PAGE.
VENTING
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents