Control Board Removal - kozy heat 56701 Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before
CAUTION
removing any components.
NOTE
Your components may look slightly different than ones shown.
1.
Turn fireplace off.
2.
Shut off gas supply at manual shut-off valve.
3.
Disconnect gas line flex tube from manual shut-off valve.
4.
Disconnect any wall switch, remote control or thermostat
wires from top & bottom terminals on gas valve or unplug all
components from receptacle, disconnect all wiring harnesses
attached to gas valve.
5.
Remove upper hood and upper louver.
6.
Remove glass frame assembly.
7.
Remove logs, pilot shield and bottom refractory panels.
LP gas models: Remove LP log plate.
8.
Remove refractory panel set (if installed).
9.
Remove burner tube from firebox by lifting up off tabs,
sliding to left & off orifice.
10. Remove front log supports. Save supports and screws.
11. Remove log grate/burner heat shield.
12. Remove and save (6) screws securing control board, lift board
out of firebox being careful not to damage sealing gasket
lying underneath.
LP GAS MODEL: LP LOG PLATE
Figure 25a

CONTROL BOARD REMOVAL

PILOT SHIELD
BURNER TUBE
FRONT LOG SUPPORTS
LOG GRATE / BURNER HEAT SHIELD
REMOVE (6) SCREWS
Figure 25b
25