200 - 299, Memory Test Error Codes - Compaq ProLiant ML330 Maintenance And Service Manual

Desktop
Hide thumbs Also See for ProLiant ML330:
Table of Contents

Advertisement

200 – 299, Memory Test Error Codes
The 200 series of diagnostic error codes identifies failures with the memory subsystem.
Error Code
200-XX
201-XX
202-XX
203-XX
204-XX
205-XX
206-XX
207-XX
208-XX
210-XX
Memory Test Error Codes
Description
Invalid memory configuration.
Memory machine ID test failed.
Memory system ROM checksum
failed.
Memory write/read test failed.
Memory address test failed.
Walking I/O test failed.
Increment pattern test failed.
Invalid memory
configuration-check memory
module installation. Memory
modules installed have 8K refresh.
Invalid memory speed detected –
check DIMM installation. Slow
memory modules may cause data
loss.
Random pattern test failed.
Diagnostics and Troubleshooting 3-35
Table 3-4
Recommended Action
Reinsert memory modules in correct location and retest.
1.
Replace the system ROM and retest.
2.
Replace the processor and retest.
3.
Replace the system board and retest.
1.
Replace the memory module and retest.
2.
Replace the processor and retest.
3.
Replace the system board and retest.
Replace memory modules.
Replace memory modules with timing greater than
60 ns.
1.
Replace the memory module and retest.
2.
Replace the processor and retest.
3.
Replace the processor board and retest.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents