Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1793-Drive Array
None
– Array
Accelerator
Battery Depleted
– Data Lost.
(Error message
1794 also
displays.)
1794-Drive Array
None
– Array
Accelerator
Battery Charge
Low.
Array Accelerator
is temporarily
disabled.
Array Accelerator
will be re-enabled
when battery
reaches full
charge.
1795-Drive Array
None
– Array
Accelerator
Configuration
Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily
disabled.
1796-Drive Array
None
– Array
Accelerator Not
Responding.
Array Accelerator
is temporarily
disabled.
Probable Source of
Action
Problem
This error indicates
Power was not restored within 8 to
that while the system
10 days. Perform orderly system
was in use, power
shutdowns to avoid data remaining in
was interrupted
the array accelerator.
while data was in the
array accelerator
memory.
Array accelerator
batteries failed. Data
in array accelerator
has been lost.
Warning that the
Replace the array accelerator board if
battery charge is
batteries do not recharge within
below 75%. Posted
36 power-on hours.
writes are disabled.
This error indicates
Match the array accelerator to the
that while the system
correct drive array, or run the BIOS
was in use, power
Setup Utility to clear the data in the
was interrupted
array accelerator.
while data was in the
array accelerator
memory.
The data stored in
the array accelerator
does not correspond
to this drive array.
Array accelerator is
1.
defective or has
been removed.
2.
Diagnostics and Troubleshooting 3-31
Check that the array accelerator is
properly seated.
Run the BIOS Setup Utility to
reconfigure the Compaq IDA-2
without the array accelerator.