Compaq ProLiant ML330 Maintenance And Service Manual page 67

Desktop
Hide thumbs Also See for ProLiant ML330:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1767-Slot X Drive Array Option ROM is Not Programmed Correctly
or may Conflict with the Memory Address Range of an ISA Card.
Check the Memory Address Configuration of installed ISA Card(s) or
run Options ROMPaq Utility to attempt SMART-2/E Option ROM
Reprogramming.
1768-Slot X Drive
None
Array – Resuming
logical drive
expansion process
1769-Slot X Drive
None
Array – Drive(s)
disabled due to
failure during
expand. Select F1
to continue with
logical drives
disabled. Select
F2 to accept data
loss and to
re-enable logical
drives.
1770-Slot X Drive
None
Array – Critical
Drive Firmware
Problem Detected
– Please upgrade
firmware on the
following drive(s)
using Options
ROMPaq
(available from
www.compaq.co
m): SCSI Port Y
SCSI ID Z
(RESUME = F1 OR
F2 KEY)
1771-Primary
None
Disk Port Address
Assignment
Conflict
1772-Secondary
None
Disk Port Address
Assignment
Conflict
Probable Source of
Action
Problem
Remove or reconfigure conflicting ISA
cards, especially any cards that are not
recognized by the BIOS Setup Utility. Try
reprogramming the SMART-2/E
Controller ROM using the latest Options
ROMPaq (version 2.29 or higher).
SMART-2 Controller
No action required. This message
error detected.
displays whenever a controller reset or
power cycle occurs while array
expansion is in progress.
SMART-2 Controller
Data has been lost while expanding the
error detected.
array; therefore, the drives have been
temporarily disabled. Press F2 to accept
the data loss and re-enable the logical
drives. Restore data from backup.
Firmware update
The indicated drives are running
need indicated.
firmware that is known to cause
intermittent problems. Use the Compaq
"Options ROMPaq" utility to upgrade
firmware on all drives to the latest
revision.
Acquire from the Compaq website:
http://www.compaq.com/support
Internal and external
Run the BIOS Setup Utility and correct.
hard drive controllers
are both assigned to
the primary address.
Address assignment
Run the BIOS Setup Utility and correct.
conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Diagnostics and Troubleshooting 3-23
continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents