Compaq ProLiant ML330 Maintenance And Service Manual page 71

Desktop
Hide thumbs Also See for ProLiant ML330:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1785-Slot X Drive
None
Array not
Configured
(followed by one
of the following):
(1) Run Compaq
Array
Configuration
Utility
(2) No drives
detected
(3) Drive positions
appear to have
changed – Run
Drive Array
Advanced
Diagnostics if
previous positions
are unknown.
Then turn system
power OFF and
move drives to
their original
positions.
(4) Configuration
information
indicates drive
positions beyond
the capability of
this controller.
This may be due
to drive movement
from a controller
that supports
more drives than
the current
controller.
(5) Configuration
information
indicates drives
were configured
on a controller
with a newer
firmware version.
(RESUME = F1
KEY)
Probable Source of
Action
Problem
Drive array
(1) Run the Compaq Array Configuration
configuration not
Utility.
detected.
(2) Power down the system and check
SCSI cable connections to make sure
drives are attached properly.
(3) Run Array Diagnostic Utility if
previous positions are unknown. Then
power down the system and move
drives to their original positions.
(4) To avoid data loss, power down the
system and reattach drives to the
original controller.
(5) To avoid data loss, reattach drives to
the original controller or upgrade the
controller firmware to the version on the
original controller using Option
ROMPaq.
Select F1 to resume.
Diagnostics and Troubleshooting 3-27
continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents