Compaq ProLiant ML330 Maintenance And Service Manual page 69

Desktop
Hide thumbs Also See for ProLiant ML330:
Table of Contents

Advertisement

Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
1777-Slot X Drive
None
Array – ProLiant
Drive Storage
Enclosure
Problem Detected
(followed by one
or more of the
following):
SCSI Port Y:
Cooling Fan
Malfunction
Detected
SCSI Port Y:
Overheated
Condition
Detected
SCSI Port Y:
Side-Panel must
be Closed to
Prevent
Overheating
SCSI Port Y:
Redundant Power
Supply
Malfunction
Detected
SCSI Port Y: Wide
SCSI Transfer
Failed
SCSI Port Y:
Interrupt Signal
Inoperative
(RESUME = F1
KEY)
Probable Source of
Action
Problem
I
Temperature
violation detected.
I
I
Diagnostics and Troubleshooting 3-25
Check cooling fan operation by
placing hand over fan. Verify
internal plenum cooling fan in
tower servers or storage systems is
operational. If fan is not operating,
check for obstructions and verify all
internal connections. Replace unit
side panel if removed.
If the ProLiant Storage System
power LED is amber instead of
green, this indicates a redundant
power supply failure.
Check SCSI cables. If the message
indicates to check SCSI cables,
verify your cabling against the
diagrams in your Compaq Smart
Array Controller user guide. If the
routing is correct, replace cables on
the specified port until the POST
message is eliminated.
continued

Hide quick links:

Advertisement

Table of Contents
loading