3-20 Compaq ProLiant ML330 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
1721-Slot X Drive
Array – Drive
parameter
tracking predicts
imminent failure.
The following
devices should be
replaced when
conditions permit.
Do not replace
drive unless all
other drives in the
array are on-line!
Back up data
before replacing
drive(s) if using
RAID 0.
1721- SMART
SCSI Hard Drive
detects imminent
failure
1724-Slot X Drive
Array – Physical
Drive Position
Change(s)
Detected –
Logical drive
configuration has
automatically
been updated.
RESUME = F1 KEY
1726-Slot X Drive
Array – Array
Accelerator
Memory Size
Change Detected.
– Array
Accelerator
configuration has
automatically
been updated.
continued
Audible Beeps
Probable Source of
Problem
None
Monitor and
performance
threshold exceeded
condition.
None
Indicated drive has
reported a SMART
predictive-failure
condition and may
fail in the future.
None
Drive change
detected.
None
Configuration
updated.
Action
Replace the drive when it is reasonable
for you to do so. The drive has not
failed, but Compaq recommends you
replace the drive.
If this drive is part of a
non-fault-tolerant configuration, back
up all data before replacing the drive,
and restore all data afterward.
-Or-
If this drive is part of a fault-tolerant
configuration, do not replace this drive
unless all other drives in the array are
online.
Press F1 to resume.
The logical drive configuration has been
updated automatically following
physical drive position changes. Press
F1 to resume.
The array accelerator configuration has
been updated automatically due to
replacement of the array accelerator (or
controller), with one having different
cache memory size. Press F1 to
resume.