Download Print this page
Compaq BL10e - HP ProLiant - 512 MB RAM Update Manual
Compaq BL10e - HP ProLiant - 512 MB RAM Update Manual

Compaq BL10e - HP ProLiant - 512 MB RAM Update Manual

Iss technology update, volume 7, number 9
Hide thumbs Also See for BL10e - HP ProLiant - 512 MB RAM:

Advertisement

ISS Technology Update
ISS Technology Update
Volume 7, Number 9
Keeping you informed of the latest ISS technology
"on-demand" technology ........................................................................................................................ 1
Use iLO Advanced to capture server event video...................................................................................... 2
HP Industry Standard Servers - a leader in industry standards for storage .............................................. 4
Recently published industry standard server technology papers ............................................................ 13
Contact us ............................................................................................................................................. 13
Quick tips for differences in energy efficiency between online "double-
conversion" technology and online "on-demand" technology
This quick tip first defines online "on-demand" technology and online "double-conversion" technology. It then contrasts the
energy efficiency performance delivered by these two technologies, each of which uses a different method to ensure a reliable
power source for continuous data center operations.
Online "double-conversion" technology
Online double-conversion is currently the technology that most data centers use for their uninterruptible power supply (UPS)
systems. In this type of UPS, the inverter is always on; it continuously converts AC to DC and then DC to AC. This generates a
pristine, or very low-distortion, sinusoidal waveform; however, efficiency is significantly lower than with online on-demand.
Online "on-demand" technology...plus double conversion
Online on-demand is an energy efficient technology that allows incoming power to connect directly to the load through
protected circuits when the incoming power is within specifications. When the power is not within specifications, the double-
conversion technology takes over to regulate the incoming voltage to an acceptable level for the load. Both online on-demand
and double-conversion modes protect the critical load from voltage fluctuations and from damaging transients that can originate
at the utility. And in the event the power goes out completely, the energy from the battery is converted to provide power to the
load until the utility returns service or until a graceful equipment shutdown becomes necessary.
Volume 7, Number 9
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the BL10e - HP ProLiant - 512 MB RAM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Compaq BL10e - HP ProLiant - 512 MB RAM

  • Page 1: Table Of Contents

    ISS Technology Update Volume 7, Number 9 ISS Technology Update Volume 7, Number 9 Keeping you informed of the latest ISS technology Quick tips for differences in energy efficiency between online “double-conversion” technology and online “on-demand” technology ........................1 Use iLO Advanced to capture server event video..................2 HP Industry Standard Servers - a leader in industry standards for storage ..........
  • Page 2: Use Ilo Advanced To Capture Server Event Video

    ISS Technology Update Volume 7, Number 9 Differences in energy efficiency From an energy efficiency standpoint, the differences between the two technologies are as follows: • State-of-the-art, double-conversion UPS models provide 92% to 93% efficiency, while older models range from 88% to 90%. •...
  • Page 3: Additional Resources

    ISS Technology Update Volume 7, Number 9 Automatic or on-demand recording The video feature of iLO Advanced allows powerful remote troubleshooting capabilities with automatic video recording and playback: • Record and play back the last boot sequence • Record and play back the last fault sequence It is also possible to record an event on-demand: •...
  • Page 4: Hp Industry Standard Servers - A Leader In Industry Standards For Storage

    Serial Attached SCSI (SAS) HP (Compaq) initiated the development of SAS in 2001, inviting LSI Logic, Seagate, and Maxtor to join together to define a replacement for parallel SCSI that supports both enterprise-class SAS drives and desktop-class SATA drives. HP has been heavily involved in the INCITS T10 (SCSI) standards committee, and has served as the editor for the SAS-1, SAS-1.1, and SAS-...
  • Page 5 ISS Technology Update Volume 7, Number 9 Institute of Electrical and Electronics Engineers (IEEE) HP participates in several IEEE 802.1 and 802.3 Ethernet (the underlying transport for iSCSI and FCoE) working groups. Work is underway defining 40 Gbps and 100 Gbps Ethernet, Data Center Ethernet (lossless features critical for FCoE), and Energy Efficient Ethernet (power down idle links).
  • Page 6: Meet The Expert-Mark Fletcher (Confessions Of An Iss "Hitman")

    ISS Technology Update Volume 7, Number 9 Meet the Expert—Mark Fletcher (confessions of an ISS “hitman”) Mark Fletcher is an HP Industry Standard Server (ISS) systems engineer who supports hardware platform teams by solving problems that normally occur during development and test cycles. That’s the answer Mark would give if you asked him what he does.
  • Page 7: Common Sm Clp Scripting Commands For Proliant Server Management, Part 2

    ISS Technology Update Volume 7, Number 9 Kevin: Mark is a constant advocate for designing products to meet our customers’ needs. Mark has worked numerous customer issues and understands the customer dissatisfaction caused by quality issues and the associated costs to customers in terms of downtime.
  • Page 8 ISS Technology Update Volume 7, Number 9 Targets record1 Properties number=1 severity=Informational date=01/29/2008 time=14:32 description=IML Cleared (iLO 2 user:Administrator) <screen output edited for readability> record3 Properties number=3 severity=NonCritical date=04/01/2008 time=14:38 description=POST Error: 1794-Drive Array - Array Accelerator Battery Charge Low Verbs cd version exit show set Properties...
  • Page 9 ISS Technology Update Volume 7, Number 9 /system1 Targets firmware Properties version=P56 date=05/21/2006 Verbs cd version exit show set bootconfig1 Targets bootsource1 Properties bootorder=1 bootsource2 Properties bootorder=2 bootsource3 Properties bootorder=3 Verbs cd version exit show set Verbs cd version exit show set log1 Targets record1...
  • Page 10 ISS Technology Update Volume 7, Number 9 cd version exit show set Targets logical_processor1 Properties current_pstate=1 pstate0_avg=9.5 pstate1_avg=90.5 pstate2_avg=0.0 pstate3_avg=0.0 pstate4_avg=0.0 pstate5_avg=0.0 pstate6_avg=0.0 pstate7_avg=0.0 <screen output edited for readability> logical_processor4 Properties current_pstate=1 pstate0_avg=11.1 pstate1_avg=88.9 pstate2_avg=0.0 pstate3_avg=0.0 pstate4_avg=0.0 pstate5_avg=0.0 pstate6_avg=0.0 pstate7_avg=0.0 Verbs cd version exit show set Properties...
  • Page 11 ISS Technology Update Volume 7, Number 9 Properties type=PCI Express width=8x Verbs cd version exit show set fan1 Properties DeviceID=Fan 1 ElementName=I/O Board OperationalStatus=Ok VariableSpeed=Yes DesiredSpeed=45 HealthState=Ok fan2 Properties DeviceID=Fan 2 ElementName=I/O Board OperationalStatus=Ok VariableSpeed=Yes DesiredSpeed=45 HealthState=Ok <screen output edited for readability> fan12 Properties DeviceID=Fan 12...
  • Page 12 ISS Technology Update Volume 7, Number 9 Additional resources For additional information on the topics discussed in this article, visit: Resource HP Integrated Lights-Out www.hp.com/go/ilo DMTF SMASH information www.dmtf.org/standards/mgmt/smash/ PuTTY and Plink www.google.com/search?q=PuTTY...
  • Page 13: Recently Published Industry Standard Server Technology Papers

    ISS Technology Update Volume 7, Number 9 Recently published industry standard server technology papers Title “Drive technology overview, 2nd edition” technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c010714 brief 96/c01071496.pdf "HP Integrated Lights-Out security, 6th edition" technology http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002127 brief 96/c00212796.pdf Industry-standard server technical papers can be found at www.hp.com/servers/technology. Contact us Send comments about this newsletter to TechCom@HP.com.