(3) Set frequency when stop-on-contact control (Pr. 270 = 1, 3) is selected
⋅ The following table lists the frequencies set when the input terminals (RH, RM, RL, RT, JOG) are selected together.
Bold frame indicates stop-on-contact control is valid.
⋅ Stop-on-contact control is disabled when remote setting function is selected (Pr. 59 = 1 to 3).
Input Signal (
= on)
RH
RM
RL
RT
JOG
CAUTION
⋅ Changing the terminal function using any of Pr. 178 to Pr. 189 may affect the other functions. Please make setting after confirming
the function of each terminal.
♦ Parameters referred to ♦
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27 (multi-speed setting)
Pr. 15 Jog frequency
Refer to page 162
Pr. 22 Stall prevention operation level, Pr. 48 Second stall prevention operation current
Pr. 22 Torque limit level
Refer to page 94
Pr. 59 Remote function selection
Pr. 72 PWM frequency selection
Pr. 79 Operation mode selection
Pr. 95 Online auto tuning selection
Pr. 128 PID action selection
Pr. 178 to Pr. 189 (input terminal function selection)
Pr. 270 = 2, 3 (load torque high speed frequency control)
Set Frequency
Pr. 4 Multi-speed setting (high speed)
Pr. 5 Multi-speed setting (middle speed)
Pr. 6 Multi-speed setting (low speed)
By 0 to 5V(0 to 10V), 4 to 20mA
input
Pr. 15 Jog frequency
Pr. 26 Multi-speed setting (speed 6)
Pr. 25 Multi-speed setting (speed 5)
Pr. 4 Multi-speed setting (high speed)
Pr. 15 Jog frequency
Pr. 24 Multi-speed setting (speed 4)
Pr. 5 Multi-speed setting (middle speed)
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Refer to page 160
Refer to page 164
Refer to page 272
Refer to page 301
Refer to page 191
Refer to page 348
Refer to page 222
Refer to page 361
Motor brake and stop operation
Input Signal (
= on)
RH
RM
RL
RT
JOG
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 26 Multi-speed setting (speed 6)
Pr. 27 Multi-speed setting (speed 7)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
By 0 to 5V(0 to 10V), 4 to 20mA
input
Refer to page 144
Set Frequency