4.7.2
Excitation ratio (Pr. 854)
Decrease the excitation ratio when you want to improve efficiency under light load. (Motor magnetic noise
decreases.)
Parameter
Name
Number
854
Excitation ratio
⋅ Note that the rise of output torque becomes slow if
excitation ratio is decreased.
This function is appropriate for applications as machine
tools which repeat rapid acceleration/deceleration up to
high speed.
REMARKS
⋅ When "1" (magnetic flux with terminal) is set in Pr. 858 Terminal 4 function assignment or Pr. 868 Terminal 1 function assignment, the
Pr. 854 setting is made invalid.
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
Initial Value
Setting Range
100%
0 to 100%
Excitation
ratio [%]
(initial value)
Pr. 854
set value
Adjustment of real sensorless vector
control, vector control
Description
Set the excitation ratio under no load.
100
0
100
Load [%]