Func-
Parameter
tion
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
Speed control gain (Advanced magnetic
89
flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1(first frequency)
101
V/F1(first frequency voltage)
102
V/F2(second frequency)
103
V/F2(second frequency voltage)
104
V/F3(third frequency)
105
V/F3(third frequency voltage)
106
V/F4(fourth frequency)
107
V/F4(fourth frequency voltage)
108
V/F5(fifth frequency)
109
V/F5(fifth frequency voltage)
110
Third acceleration/deceleration time
111
Third deceleration time
112
Third torque boost
113
Third V/F (base frequency)
114
Third stall prevention operation current 0 to 220%
Third stall prevention operation
115
frequency
116
Third output frequency detection
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting 0 to 150ms, 9999
124
PU communication CR/LF selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
Name
Setting Range
0.4 to 55kW, 9999/
0 to 3600kW, 9999
2, 4, 6, 8, 10, 12, 14, 16,
18, 20, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 1000V
10 to 120Hz
0 to 200%, 9999
Ω
0 to 50
0 to 400mΩ, 9999
Ω
0 to 50
0 to 400mΩ, 9999
Ω
0 to 50
(0 to 1000mH), 9999/
0 to 3600mΩ (0 to 400mH), 9999
Ω
0 to 50
(0 to 1000mH), 9999/
0 to 3600mΩ (0 to 400mH), 9999
Ω
0 to 500
0 to 100Ω (0 to 100%), 9999
0 to 2
0, 1, 101
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to10, 9999
0, 0.1 to 999.8s, 9999
0, 1, 2
0 to 400Hz
0 to 400Hz
Minimum
Setting
Increments
0.01/0.1kW
*2
*2
1
0.01/0.1A
*2
*2
0.1V
0.01Hz
0.1%
0.001Ω/
, 9999/
0.01mΩ
*2
*2
0.001Ω/
, 9999/
0.01mΩ
*2
*2
0.001Ω (0.1mH)/
0.01mΩ(0.01mH)
*2
*2
0.001Ω (0.1mH)/
0.01mΩ(0.01mH)
*2
*2
0.01Ω (0.1%)/
(0 to 100%), 9999/
0.01Ω (0.01%)
*2
*2
1
1
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
1
1
1
1
1
0.1s
1ms
1
0.01Hz
0.01Hz
Parameter List
Refer
Customer
Initial Value
to
Setting
Page
148,
9999
189
148,
9999
189
9999
189
200/400V
189
*5
Hz
189
60
9999
148
9999
189
9999
189
9999
189
9999
189
9999
189
0
199
0
189
9999
164
0V
164
9999
164
0V
164
9999
164
0V
164
9999
164
0V
164
9999
164
0V
164
9999
172
9999
172
9999
146
9999
159
150%
152
0Hz
152
60
Hz
246
0
333
192
333
1
333
2
333
1
333
9999
333
9999
333
1
333
60
Hz
294
Hz
294
60
73
4