Mitsubishi Electric FR-A720-0.4K Instruction Manual page 83

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

Parameter List
Func-
Parameter
tion
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
Second stall prevention operation
49
frequency
50
Second output frequency detection
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
61
Reference current
62
Reference value at acceleration
63
Reference value at deceleration
64
Starting frequency for elevator mode
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Fault code output selection
77
Parameter write selection
78
Reverse rotation prevention selection
79
Operation mode selection
72
Name
0 to 100%
0 to 400Hz
0 to 400Hz, 9999
0 to 3600/360s
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 220%
0 to 400Hz, 9999
0 to 400Hz
0 to 500A, 9999/
0 to 3600A, 9999
0, 5 to 14, 17 to 20,
22 to 25, 32 to 35, 39, 46,
50 to 57, 100
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 46, 50,
52, 53
0 to 400Hz
0 to 500/0 to 3600A
0, 0.1 to 5s, 9999/
0, 0.1 to 30s, 9999
0 to 60s
0, 1, 2, 3
0, 4
0 to 500A, 9999/
0 to 3600A, 9999
0 to 220%, 9999
0 to 220%, 9999
0 to 10Hz, 9999
0 to 5
0 to 400Hz
0 to 10, 101 to 110
0 to 10s
0
0 to 30%/0 to 10%
0 to 8, 13 to 18, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54
0 to 15/0 to 6, 25
0 to 7, 10 to 17
0 to 8
0 to 3, 14 to 17
0, 1, 2
0, 1, 2
0, 1, 2
0, 1, 2, 3, 4, 6, 7
Minimum
Setting Range
Setting
Increments
0.1%
0.01Hz
0.01Hz
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
0.01/0.1A
*2
1
1
0.01Hz
0.01/0.1A
*2
0.1s
*2
0.1s
1
1
0.01A/0.1A
*2
0.1%
0.1%
0.01Hz
1
0.01Hz
1
0.1s
1
0.1%
*2
1
1
*2
1
1
1
1
1
1
1
Refer
Customer
Initial Value
to
Page
246
10%
246
6Hz
246
9999
5s
172
9999
172
9999
146
9999
159
150%
152
0Hz
152
30Hz
246
9999
183
*2
0
253
1
253
Hz
259
60
Rated inverter
259
*2
current
9999
266
1s
266
0
169
0
278
163,
9999
*2
180
9999
180
9999
180
9999
163
0
273
Hz
152
60
0
273
1s
273
0
273
0%
207
148,
0
187
2
284
1
290
1
292
14
305
0
275
0
307
0
308
0
313
Setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents