Function assignment of external terminal and control
Setting
Signal
Positive
Negative
Name
Logic
Logic
13
113
Y13
14
114
FDN
15
115
FUP
16
116
RL
17
MC1
18
MC2
19
MC3
20
120
BOF
25
125
FAN
26
126
FIN
27
127
ORA
28
128
ORM
30
130
Y30
31
131
Y31
32
132
Y32
33
133
RY2
34
134
LS
35
135
TU
36
136
Y36
39
139
Y39
41
141
FB
42
142
FB2
43
143
FB3
44
144
RUN2 Inverter running 2
45
145
RUN3
46
146
Y46
240
Function
Output when the output power is lower than the
Zero current detection
Pr. 152 setting for longer than the time set in Pr.
153.
Output when the feedback value falls below the
PID lower limit
lower limit of PID control.
Output when the feedback value rises above
PID upper limit
the upper limit of PID control
PID forward/reverse
Output when forward rotation is performed in
rotation output
PID control.
Electronic bypass MC1
Used when the commercial power supply-
Electronic bypass MC2
inverter switchover function is used.
Electronic bypass MC3
Brake opening
Output to open the brake when the brake
sequence function is selected.
request
Fan fault output
Output at the time of a fan fault.
Output when the heatsink temperature reaches
Heatsink overheat
about 85% of the heatsink overheat protection
pre-alarm
providing temperature.
Orientation complete
(for FR-A7AP/FR-
A7AL)
When orientation is valid
*3
Orientation fault (for
FR-A7AP/FR-A7AL)
*3
Forward rotation output
Output when the motor is running in forward
(for FR-A7AP/FR-
direction.
A7AL)
*3
Reverse rotation output
Output when the motor is running in reverse
(for FR-A7AP/FR-
direction.
A7AL)
*3
Regenerative status
Output in the regenerative status under vector
output (for FR-A7AP/
control operation.
FR-A7AL)
*3
Output during pre-excitation or operation under
Operation ready 2
Real sensorless vector control.
Output when the output frequency drops below
Low speed output
the Pr. 865 setting.
Output when the motor torque rises above the
Torque detection
Pr. 864 value.
In-position (for FR-
Output when the number of droop pulses has
A7AP/FR-A7AL)
fallen below the setting value.
*3
Start time tuning
Output on completion of start-time tuning.
completion
Speed detection
Output when the actual motor speed (estimated
Second speed
actual speed value) reaches the Pr. 42 (Pr. 50,
detection
Pr.116) setting.
Third speed detection
⋅ Output during forward rotation or the reverse
rotation signal is ON.
⋅ Output at deceleration even during forward
rotation or the reverse rotation signal is OFF.
(Does not output during pre-excitation LX is
ON.)
⋅ Output during the orientation command signal
(X22) is ON.
⋅ Switched ON when the servo is ON (LX-ON)
under position control. (Switched OFF when
the servo is OFF (LX-OFF))
Inverter running and
Output when the inverter is running and start
start command is on
command is ON.
During deceleration at
Output when the power failure-time deceleration
occurrence of power
function is executed.
failure
(retained until release)
Operation
Related
Refer
Parameters
to Page
Pr. 152, Pr. 153
248
Pr. 127 to Pr. 134,
361
Pr. 575 to Pr. 577
Pr. 135 to Pr. 139,
369
Pr. 159
Pr. 278 to Pr. 285,
217
Pr. 292
Pr. 244
385
-
410
Pr. 350 to Pr. 366,
Pr. 369, Pr. 393,
220
Pr. 396 to Pr. 399
244
-
244
244
-
242
Pr. 865
246
Pr. 864
249
Pr. 426
140
Pr. 95, Pr. 574
199
Pr. 42, Pr. 50,
246
Pr. 116
-
242
-
242
Pr. 261 to Pr. 266
270