Communication operation and setting
Real-time monitor
Refer to page 253 for details of the monitor description.
Register
Definition
Output frequency/
40201
speed
*2
40202
Output current
40203
Output voltage
Frequency setting
40205
value/speed setting
*2
40206
Running speed
40207
Motor torque
Converter output
40208
voltage
Regenerative brake
40209
duty
Electronic thermal
40210
relay function load
factor
Output current peak
40211
value
Converter output
40212
voltage peak value
...........Specifications differ according to the date assembled. Refer to page 484 to check the SERIAL number.
*1
The setting depends on capacities. (55K or lower / 75K or higher)
*2
When Pr. 37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 251)
*3
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
*4
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
b15
*5
Details of option input terminal monitor 1 (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0)-all terminals
are OFF when an option is not fitted
b15
X15
X14
X13
*6
Details of option input terminal monitor 2 (input terminal status of FR-A7AX when the terminal is ON: 1, when the terminal is OFF: 0, —:
undetermined value)-all terminals are OFF when an option is not fitted
b15
*7
Details of option output terminal monitor (output terminal status of FR-A7AY/A7AR when the terminal is ON: 1, when the terminal is OFF: 0, —:
undetermined value)-all terminals are OFF when an option is not fitted
b15
356
Increments
Register
0.01Hz/1
40213
Input power
0.01A/
40214
Output power
0.1A
*1
0.1V
Input terminal
40215
status
0.01Hz/1
Output terminal
40216
status
1r/min
40217
Load meter
0.1%
Motor excitation
40218
current
0.1V
40219
Position pulse
Cumulative
0.1%
40220
energization time
40222
Orientation status
0.1%
Actual operation
40223
time
0.01A/
40224
Motor load factor
0.1A
*1
40225
Cumulative power
40232
Torque command
0.1V
CS
RES
STOP
X12
X11
X10
X9
RA3
Definition
Increments
0.01kW/
0.1kW
*1
0.01kW/
0.1kW
*1
*3
*4
0.1%
0.01A/
0.1A
*1
1h
1h
0.1%
1kWh
0.1%
MRS
JOG
RH
RM
ABC2 ABC1
X8
X7
X6
X5
RA2
RA1
Y6
Y5
Register
Definition
Torque current
40233
command
40234
Motor output
40235
Feedback pulse
Motor temperature
40246
40250
Power saving effect
Cumulative saving
40251
power
40252
PID set point
PID measured
40253
value
40254
PID deviation value
Option input
40258
terminal status1
*5
Option input
40259
terminal status2
*6
Option output
40260
terminal status
*7
RL
RT
AU
FU
OL
IPF
X4
X3
X2
Y4
Y3
Y2
Increments
0.1%
0.01/
0.1kW
*1
1°C
Variable
Variable
0.1%
0.1%
0.1%
b0
STR
STF
b0
SU
RUN
b0
X1
X0
b0
DY
b0
Y1
Y0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents