Mitsubishi Electric FR-A720-0.4K Instruction Manual page 132

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

(2) Operation transition
Speed limit value is
increased up to preset value
according to the Pr.7
Acceleration time setting.
Speed
Speed limit
Start signal
Output torque
⋅ When "0" is set in Pr. 7 or Pr. 8, speed control is exercised upon powering OFF a start signal and the output torque is
limited at the torque limit value.
Speed
Start signal
Output torque
Item
External operation
Start signal
PU operation
Torque command
Select the input method of torque command and input the torque command.
Speed limit
Select the input method of speed limit and input the speed limit value.
Speed limit value
Torque control
Speed control is peformed during speed
limit. (Thus, torque according to the
commanded is not developed.)
Torque control
Limit at the torque limit value
Description
STF, STR signal
and
of FR-DU07, FR-PU07 or FR-PU04
Torque control by Real sensorless
vector control, vector control
Speed limit value is decreased
down to zero according to the Pr.8
Deceleration time setting.
Speed limit
Output torque is provided
according to the terminal 1
setting.
Speed limit value
Speed control
(speed limit)
Output torque is provided
according to the terminal 1
setting.
4
121

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents