4.13.2 Applied motor (Pr. 71, Pr. 450)

Setting of the used motor selects the thermal characteristic appropriate for the motor.
Setting is necessary when using a constant-torque motor. Thermal characteristic of the electronic thermal relay
function suitable for the motor is set.
When Advanced magnetic flux vector, Real sensorless vector control or vector control is selected, the motor
constants (SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500r/min series)) necessary for control are
selected as well.
Parameter
Name
Number
71
Applied motor
450
Second applied motor
(1) Set the motor to be used
Refer to the following list and set this parameter according to the motor used.
Pr. 71 (Pr. 450)
Setting
Pr. 71
Pr. 450
0
Standard motor (such as SF-JR)
(Pr. 71 initial value)
Mitsubishi constant-torque motor (such as SF-JRCA)
1
Standard motor (such as SF-JR)
2
Adjustable 5 points V/F (Refer to page 164)
Mitsubishi standard motor (SF-JR 4P 1.5kW or lower)
20
Vector control dedicated motor SF-V5RU (1500r/min series)
30
40
Mitsubishi high efficiency motor SF-HR
50
Mitsubishi constant-torque motor SF-HRCA
Standard motor
3
Constant-torque motor
Vector control dedicated motor SF-V5RU
13
(except for 1500r/min series).
Mitsubishi standard motor
23
(SF-JR 4P 1.5kW or lower)
Vector control dedicated motor SF-V5RU
33
(1500r/min series), SF-THY
43
Mitsubishi High efficiency motor (SF-HR)
53
Mitsubishi constant-torque motor (SF-HRCA)
4
Standard motor
Constant-torque motor
14
Vector control dedicated motor SF-V5RU
(except for 1500r/min series).
Mitsubishi standard motor
24
(SF-JR 4P 1.5kW or lower)
Vector control dedicated motor SF-V5RU
34
(1500r/min series), SF-THY
44
Mitsubishi High efficiency motor (SF-HR)
54
Mitsubishi constant-torque motor (SF-HRCA)
Standard motor
5
Constant-torque motor
15
6
Standard motor
16
Constant-torque motor
Standard motor
7
17
Constant-torque motor
Standard motor
8
Constant-torque motor
18
9999
(initial
Without second applied motor
value)
Initial Value
Setting Range
0 to 8, 13 to 18, 20,
0
23, 24, 30, 33, 34,
40, 43, 44, 50, 53, 54
0 to 8, 13 to 18, 20,
23, 24, 30, 33, 34,
9999
40, 43, 44, 50, 53, 54
9999
Motor
Select "offline auto tuning
setting"
Auto tuning data can be read,
changed, and set
Star
connection
Delta
connection
Star
connection
Delta
connection
Selection and protection of a motor
Description
Selecting the standard motor or constant-
torque motor sets the corresponding motor
thermal characteristic.
Set when using the second motor.
(same specifications as Pr. 71)
Not function
Electronic thermal relay function
operation characteristic
Standard
Direct input of
motor
constants is
enabled
Motor
constants
direct input
+
offline auto
tuning
Constant torque
4
187