7.2.9

Setting the Alarm System

Setting the relay output (Relay Output)
Procedures
1. Open the Serviceman Menu.
2. Open the Relay Output menu by performing the following menu
3. Press the [1] key.
4. Press the [numeric] key corresponding to the item to be changed.
Setting the ALR output (ALR Output)
Procedures
1. Open the Serviceman Menu.
2. Open theALR output menu by performing the following menu
3. Press the [numeric] key corresponding to the item to be changed.
This function enables the control of ARPAALM terminal (on the terminal board
circuit).
operation.
2. Installation Menu
→ 6. Alarm System
→ 2. Relay Output
The Relay Output mode is switched.
Continuous
: The output is continuously controlled.
Intermittent
: The output is intermittenly controlled.
The item can be turned on / off.
On
: The relay output is turned on when alarm have issued.
Off
: The relay output is not turned on when alarm have issued.
2. TT CPA/TCPA
: There is a dangerous target. (tracked target)
3. AIS CPA/TCPA : There is a dangerous target. (AIS target)
4. New Target
: A new target is acquired in the automatic acquisition zone.
5. Lost
: There is a lost target. (Target Tracking / AIS).
6. RADAR Alarm
: Targets have entered the radar alarm range.
This function enables the control of ALR port (See the section 7.2.1).
operation.
2. Installation Menu
→ 6. Alarm System
→ 3. ALR Output
The item is turned on / off.
On
: The ALR sentence is output when alarm have issued.
Off
: The ALR sentence is not output when alarm have issued.
1. System Alarm
: The internal alarm.
2. TT/AIS Alarm
: Target Tracking Alarms and AIS Function Alarms.
7-21