5.8.4 Canceling Plotted Target Data

The system cancels the display of specified plotted target data.
Once plotted target data is canceled, it cannot be re-saved any more.
Procedures
1
Press the [ACQ] key.
2
Enter the plot number for cancellation, pressing [0] to [9].
3
Press the [TGT CNCL] key.
The plotted target data of the specified plot number will be canceled.
Canceling all plotted targets
Procedures
1
Press the [TGT CNCL] key for 5 seconds or more.
The plotted targets of all the plot numbers will be canceled.

5.8.5 Displaying Numeric Data of Plotted Targets

The following data is displayed for a specified plotted target:
TGT ID
Plot number
BRG
Bearing
Range
Range
Course
Target's true course
Speed
Target's true speed
CPA
CPA
TCPA
TCPA
TIME
Elapsed time
Procedures
1
Press the [TGT DATA] key.
2
Enter the plot number pressing [0] to [9].
3
Press the [ENT] key.
The data of the specified plot number will be displayed.
The mark of the target for which numeric data is displayed is changed into "
:0.1° unit
:0.01 nm unit
:0.1° unit
:0.1 kn unit
:0.01 nm unit
:0.1 min unit
:0.1 min unit
5-66