Chapter 3 Setup
2.4

Cases that Require Configuration

Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as factory setting. Other than cases described below, do not change the settings. A list of SETUP
parameters and factory settings are described in Chapter 2 (1. System BIOS) in "Maintenance Guide".
Category
Basic
Change date and time
On/Off NumLock on power
ON
On/Off the function to
display the NEC logo during
POST
Memory
Add or change DIMM
Use memory RAS feature
Optional
Disable Option ROM Scan
board
of installed option board
Boot
Change the boot order of
devices
Use remote power on
function (via modem)
Use remote power on
function (via RTC alarm)
Use console redirection
feature
Security
Set a password
Restrict bootup by entering
password
UPS
When the server is supplied
Powerlink
with power from UPS,
always turn on the power.
If it is turned off by using
POWER switch, leave it
OFF even when UPS
supplies power.
Keep the power OFF even
when UPS supplies power.
130
Description
Main → System Date
Main → System Time
Boot → Bootup Numlock State
Boot → Quite Boot → Disabled
Advanced → Memory
Configuration → Memory Retest
→ Yes
Advanced → Memory
Configuration → Memory RAS
Mode → change to RAS mode
Advanced → PCI Configuration →
PCI Device Controller and Option
ROM Settings → PCIXX Slot
Option ROM → Enabled
Boot → Boot Option Priorities →
Change the boot priority
Advanced → Advanced Chipset
Configuration → Wake On Ring →
Enabled
Advanced → Advanced Chipset
Configuration → Wake On RTC
Alarm → Enabled
Advanced → Serial Port
Configuration → Console
Redirection Setting → Change
respective setting.
Security → Administrator
Password → Enter a password
Security → User Password →
Enter a password
Security → Password on Boot →
Enabled
Server → Power Control
Configuration → AC-LINK →
Power On
Server → Power Control
Configuration → AC-LINK → Last
State
Server → Power Control
Configuration → AC-LINK → Stay
off
Express5800/R120d-2M User's Guide
To be changed
Configurable on OS
By pressing the <Esc> key,
prevent the display of the
logo.
After rebooting, Memory
Retest changes No
automatically.
Some of RAS features may
not be used depending on
DIMM configuration.
XX is PCI slot number of the
option board
When you use
EXPRESSBUILDER, set
CD/DVD to the highest
priority.
If password is set, a
message to enter password
is displayed at next time
SETUP is launched.
Can be selected when
password is set.