Configuring Buzzer Out Settings - Digimerge DHU600 Series Instruction Manual

Digimerge dhu600 series digital video surveillance recorder
Table of Contents

Advertisement

Using Web Remote Viewer
3. Under the Mode drop-down menu, select Latched or Transparent.
• Latched alarms continually "beep" long after a camera detects motion. Transparent alarms
"beep" only when there is motion. Once the camera does not detect motion, the "beeping"
stops.
4. Under the Type drop-down menu, select N/O (normally open) or N/C (normally closed).
5. Under the HDD Event drop-down menu, select ON or OFF to enable or disable a hard disk
failure to send out an e-mail notification.
6. For each channel, select which events you want to trigger an alarm (Figure 38.4).
• For example, you may want a video loss and motion event in channel 2 to trigger an alarm.
Figure 38.4 Alarm output selection.
7. Click OK to save your settings.

Configuring Buzzer Out Settings

To configure Buzzer Out settings:
1. Click the Buzzer Out sub-menu on the navigation bar on the left (Sensor>Buzzer Out). The
Buzzer Out Setting window opens.
Figure 38.5 Buzzer Out Settings window.
2. Under the Operation drop-down menu, select Enable configure buzzer settings.
3. Under the Mode drop-down menu, select Transparent or Latched.
4. Under the HDD Event drop-down menu, select ON to enable to trigger the buzzer when an
HDD event occurs.
5. For each channel, select which events you want to trigger the buzzer (Figure 38.4).
• For example, you may want a video loss and motion event in channel 2 to trigger a buzzer.
6. Click OK to save your settings.
90
In this example, Video Loss and
Motion is selected in channel 2.
If video loss or motion occurs in
channel 2, it triggers an alarm
output.