SiEN12-710A
1.7
Removal of the Compressor
Procedure
Step
1
Remove the terminal
cover.
2
Disconnect the flag-
shaped terminals.
3
Detach the terminals by
long nose pliers.
Undo the hooks by a
flat screwdriver to
remove the overheating
protector.
4
Detach the overload
protector.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Terminal cover
Protection bushing
for lead wires
Yellow (V)
" Be careful so as not to burn
the compressor terminals or
the name plate.
Make a note.
(R7637)
Red (U)
Blue (W)
(R7638)
(R7639)
(R7640)
Outdoor Unit
Points
175