Outdoor Unit
1.5

Removal of the Propeller Fan / Fan Motor

Procedure
Step
1. Remove the propeller fan
1
Loosen the washer
fitted nut (M10) by an
open-ended spanner to
remove the propeller
fan.
2. Remove the fan motor
1
Disconnect the
connector [S70] for the
fan motor from the
PCB.
170
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
[S70]
Points
(R7618)
(R7619)
" When assembling, align
mark of the propeller fan with
D-cut section of the motor
shaft.
(R7620)
(R7621)
Removal Procedure