Removal Of Propeller Fan And Fan Motor - Daikin FTKS25BVMB Service Manual

Hide thumbs Also See for FTKS25BVMB:
Table of Contents

Advertisement

Outdoor Unit
2.4
Removal of
Procedure
disassembling work.
Step
Disconnect the fan motor
connector S70.
Release the lead-wires
1
of the fan motor from
the groove of the switch
box.
The propeller fan can
2
be removed when the
washer faced nut (M8)
is removed.
Remove two screws for
3
removing the fan motor.
The lead wires are
disengaged by raising
the hooks which fix the
lead wires.
162
Propeller Fan
Warning
Be sure to turn off all power supplies at least 10 min. before
Procedure
and
Fan Motor
SiBE04-302
Points
Remove the external plates
and the drip proof cover
protecting the electric parts.
Be sure to avoid forgetting to
restore the shelter and to
avoid loosing or damaging it.
When restoring, match the M
mark of the propeller fan with
the D-cut of the motor shaft.
The fan should be restored
so that the mark
will be at
upper part of the fan motor.
Removal Procedure